Strona 1 - AQUAPRO!OWN E R’S!MANUAL!

!!!!!!AQUAPRO!OWN E R’S!MANUAL!!4438!Muhlhauser!Road!!Suite!600!Hamilton,!OH!45011!877F278F2797!

Strona 2 - TABLE OF CONTENTS

7THE FOLLOWING CODES WILL BE DISPLAYED AS PARTOF THE NORMAL OPERATION OF THE HEATER:Operational & Programming CodesFLO... No Water Flow Detected

Strona 3

8HEATER CONTROLS...continuedStart Up & Setting Operating Controls Owner-Level Programming Instructions (Complete)Covered within this section

Strona 4 - HOW A HEAT PUMP WORKS

94. Selecting Pool/Spa Thermostat Settings:A. Press the [POOL/SPA] key to toggle between the pool and the spa temperature set points.B. The pool/spa L

Strona 5 - Safety Signals

10HEATER CONTROLS...continuedStart Up & Setting Operating Controls(ULC Continued on Next Page)8. User Lock Code Option [ULC]...continued:A

Strona 6 - Water Temperature Safety

11HEATER CONTROLS...continuedStart Up & Setting Operating Controls9. Selecting Call-Flex Pump Options [CFO]:General Information:The Call-Flex

Strona 7 - Getting Started

12MAINTENANCEOPERATIONAL RECOMMENDATIONS &The information in this section is written primarily for the Home Owner, but may also apply to servicin

Strona 8 - INTERRUPTED

13 It is important to operate and maintain the filter according to the manufacturer's specifications.As a filter gets dirty, the water flow to t

Strona 9 - HEATER CONTROLS

14Maintain Proper Clearances Around Heater For maximum efficiency, proper air flow clearances around heater must be maintained. It is important t

Strona 10 - CAUTION !

15Spa Heating & Spa Setback Option...Air blowing into your spa, while it is being brought to temperature, will very often neutralize or partially

Strona 11 - HEATER CONTROLS...continued

16Calculating Initial Heating TimeThe time it takes to initially warm your pool or spa depends on several factors.First, determine how many gallons

Strona 12

3TABLE OF CONTENTSHOW A HEAT PUMP WORKS ------------------------------------------1SAFETY INFORMATION------------------------------------------------2

Strona 13

17Seasonal Use & Shut DownDuring the Swim Season: During the swim season, even if the pool or spa is not in use, allow water to flow through t

Strona 14

181. Disconnect all electrical power to the heater; turn OFF circulating pump.2. At the two (2) connection unions, disconnect the plumbing to the heat

Strona 15 - WARNING !

19Planned Maintenance ProgramJust as you would have yearly service performed on your air-conditioning system, regular inspectionand maintenance of y

Strona 16

20Heat Pump Fails to Operate...Is the display illuminated?If not, ensure the main breaker (located at the power supply panel) and the disconnect s

Strona 17

21TROUBLESHOOTING FLOWCHARTHeat Pump Fails to OperateIs the heateroperating correctly ?Is the heateroperating correctly ?Is the heater operating corre

Strona 18 - Heating Tips

22TROUBLESHOOTING FLOWCHARTSTARTIs the air being dischargedout of the top of the heater 9-12degrees cooler than theoutside air?STARTIs the air being

Strona 19

23TROUBLESHOOTING FLOWCHARTWater Coming from Heat PumpSTARTHas the "Heating" lamp beenilluminated?STARTHas the "Heating" lamp

Strona 20 - Important !!!

24What We Need to Know When You Call UsIf you should need to call AquaPro for service or parts, please have the follow-ing information ready:Model: _

Strona 21 - ILL VARY BY MODEL

LIMITED WARRANTYFor (7) years for the state of Florida and (2) years for all other US states and Canada, Heating Solutions, LLC will repair or replace

Strona 22 - INFORMATION

4TABLE OF CONTENTS(CONTINUED)MAINTENANCE AND GENERAL OPERATION...CONTINUED:Heating Tips--------------------------------------------------------15- Hea

Strona 23 - TROUBLESHOOTING

1HOW A HEAT PUMP WORKSTHE FOLLOWING EXPLANATION IS PROVIDED TO HELP YOU IN UNDERSTANDINGWHAT TO EXPECT FROM YOUR HEAT PUMP…A Heat Pump Does Not Ma

Strona 24 - TROUBLESHOOTING FLOWCHART

2Used and maintained properly, your heat pump will provide year-upon-year of safe andeconomical service. However, as with any mechanical or el

Strona 25

3Refrigerant Circuit Service Only byQualified, EPA Certified TechnicianNotice: Heater NOT Repairable by OwnerWater Chemistry SafetyWater Temperature S

Strona 26

4HEATING- QUICK START & STOPGetting Started(Quick-Start & Stop Continued Next Page)1. Verify Electrical Power is Present at Heater:A. Ens

Strona 27 - CONTACTING THE FACTORY

5NOTE: THE HEATER CONTROLLER INCORPORATES AN ANTI-SHORT CYCLE TIME DELAY. SHOULD OPERATION BEINTERRUPTED, COMPRESSOR RESTART WILL BE DELAYED BY APPRO

Strona 28 - LIMITED WARRANTY

6HEATER CONTROLSControl Panel Layout(APPEARANCE VARIES BY MODEL)Control Buttons, Indicator Lights, & Display(AS INDICATED BY CIRCLED NUMBERS)1) PO

Komentarze do niniejszej Instrukcji

Brak uwag